Follow the safety clearance specifications when installing the sauna heater. Thin panel is not a suitable mounting base. The mounting base must be reinforced with timber behind the panel. The minimum clearances specified on page 8 must be followed also in case the sauna room wall materials are incombustible.
Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may cause a fire hazard.
A single sauna heater is allowed per a sauna room.
Sauna heater safety clearances



Safety Clearances
| Effect | Sauna Room | Minimum distance to: | Minimum distance for wall bracketf | Minimum distance to niche | Stone | |||||
| kW | Volume (m3) | Height (mm) | Side wall A (mm) | In front of D (mm) | Ceiling F (mm) | Floor K (mm) | B (mm) | J (mm) | E (mm) | n (kg) |
| 3.0 4.5 6.0 8.0 9.0 |
2-4 3-6 5-9 8-13 9-14 |
1900 1900 1900 1900 1900 |
30 50 70 100 100 |
50 80 100 150 200 |
1200 1200 1250 1250 1250 |
120 120 120 120 120 |
50 70 90 120 120 |
390 390 390 390 390 |
540 580 650 750 – |
15 15 23 23 23 |